Sound Level Meter Model 831 Larson Davis |
||
Sound Level Meter Specifications |
||
Averaging ( Integration method ) |
Linear or Exponential |
|
RMS Time Weighting |
Slow, Fast or Impulse |
|
Frequency Weightings |
A, C or Z |
|
Peak Detector Frequency Weighting |
A, C or Z |
|
Gain |
0 dB or +20 dB |
|
Exchange Rates |
3, 4, 5, or 6 dB with optional 831-IH |
|
Sample Rate |
51,200 Hz |
|
Peak Rise Time |
30 μμs |
|
Physical Characteristics |
||
Length with Microphone and Preamplifier |
11.35 in |
29.0 cm |
Length, Instrument Body Only |
8.8 in |
22.4 cm |
Width |
2.8 in |
7.1 cm |
Depth |
1.6 in |
4.1 cm |
Weight with Batteries, No Preamplifer or Microphone |
13.6 oz |
390 g |
Weight with Batteries, Preamplifer and Microphone |
1.2 lb |
550 g |
General Specifications |
||
Reference level |
114.0 dB re. 20 μPa |
|
Reference level range |
Single large range for SLM Normal for OBA option, Gain 0 dB |
|
Reference frequency |
1000 Hz |
|
Reference direction |
0° is perpendicular to the microphone diaphragm |
|
Temperature |
≤ ± 0.5 dB error between +14 to +122 °F ( -10 to 50 °C ) |
|
Storage temperature |
-13 to +158 °F ( -25 to +70 °C ) |
|
Humidity |
≤ ± 0.5 dB error from 30% to 90% relative humidity at 104°F (40 °C) |
|
Equivalent Microphone Impedance |
12 pF for Larson Davis 1/2 in microphone |
|
Range Level Error ( OBA option ) |
≤ ± 0.1 dB relative to the reference range |
|
Digital Display Update Rate |
Four times per second ( 0.25 sec between updates ). First display indication is available 0.25 seconds after initiation of a measurement. |
|
Effect of an Extension Cable |
None ( up to 200 ft or 61 m with EXCxxx cable ) |
|
Electrostatic Discharges |
The instrument is not adversely affected by electrostatic discharges |
|
Extended Weather Options |
-40 to +158 ºF ( -40 to +70 ºC ) operation with CER-831-E |
|
Resolution Specifications |
||
Levels |
0.1 dB |
|
Dose |
0.1 % |
|
Elapsed time |
0.1 second |
|
Real time clock |
1 second |
|
Calendar Through |
31 Dec 2100 |
|
Integration Time |
||
Time Averaged Levels and Sound Exposure Levels ( s ) |
||
Minimum |
0.1 second |
|
Maximum with Daily Autostore Enabled |
Unlimited |
|
Maximum with Daily Autostore Disabled |
> 23 days with error < 0.5 dB |
|
Dosimeter Metrics : TWA, Dose ( s ) |
||
Minimum |
0.1 second |
|
Maximum |
Unlimited |
|
Ln Statistics |
||
Number of selectable parameters |
6 in xx.xx% format, visible on the Model 831 |
|
Storage of Complete Table |
0.1 dB Steps |
|
Spectral Statistics |
Requires Octave Analysis option ( 831-OB3 ) |
|
Markers |
||
Number of Markers |
10 |
|
Prenamed Markers |
5 : Truck, Automobile, Motorcycle, Aircraft, Exclude |
|
Link Marker to Automatic Sound Recording |
Yes, requires Sound Recording option ( 831-SR ) |
|
Back Erase |
||
Back Ease Time |
5 or 10 seconds |
|
Supported Modes |
Manual |
|
Measurement Control Modes |
||
Available Modes |
Manual Stop, Timed Stop, Stop when Stable, Continuous, Single Block Timer, Daily Block Timer |
|
Timed Stop Time in |
hh:mm:ss |
|
Stop When Stable |
Delta level in xx.x dB and time in hh:mm:ss |
|
Continuous with Daily Auto-Store |
1, 2, 4, 6, 12, 24, 48, 96 or 144 files per day, automated file numbering “yymmddnn.LD0” |
|
Continuous Restart on Power Failure |
Automatic if powered by 12VDC |
|
Single Block Timer |
Start date and time to End data and time |
|
Daily Block Timer |
Up to 3 blocks with each start and end date, blocks can cross date line |
|
Clock Stability |
||
< 1 sec in 24 hours, at 75 ºF ( +24 ºC ) |
||
< 10 sec in 30 days, at -40 to +158 ºF ( -40 to +70 ºC ) |
||
Digital Voice Annotation |
||
Annotate Recordings |
Use headset ( ACC003 ) or measurement microphone |
|
Recording Sample Rate |
8 ksps |
|
Listening Options |
On the Model 831 or using processing software for .wav files |