Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.
MA160 Infrared Moisture Analyzer Sartorius |
|
Technical Specifications |
|
Max. weighing capacity |
200 g |
Reproducibility, typical |
Starting at an initial sample weight of approx. 1 g : ±0.2 %, |
Starting at an initial sample weight of approx. 5 g : ±0.05 % |
|
Readability |
1 mg, 0.01 % |
Typical sample quantity |
5 g – 15 g |
Display modes for results |
Moisture content in % M and % g | dry weight in % S and g | ATRO ( ratio ) in % M/S |
Temp. range and settings |
40 °C – 200 °C, in increments of 1 °C |
Standby temperature selectable from 50 °C – 120 °C |
|
Sample heating |
Infrared heating using an AURI heating unit, 600 W |
Heating programs |
Standard drying, gentle drying, MA35 mode |
Shutoff parameter |
Fully automatic, semi-automatic, manual and with timer settings |
Forceps for samples |
For easy handling of sample pans |
Data interface |
Mini USB port; automatic printer detection, direct transfer to Microsoft® Office |
Data transfer |
SD card; function for importing and exporting methods and results |
Housing dimensions ( W+ D + H ) |
215 x 400 x 210 mm ( 8.5" + 15.7" + 8.3" ) |
Weight |
Approx. 6.2 kg ( approx. 13.6 lbs.) |
Accessories |
|
6965542 |
Disposable sample pans, 80 units, aluminum, 90 mm ɸ |
6906940 |
Glass fiber pads for analysis of pasty and fatty samples, hard quality; 80 units; 90 mm ɸ |
6906941 |
Glass fiber pads for analysis of liquid and fatty samples, soft quality; 200 units; 90 mm ɸ |
YHP01MA |
ReproEasy pads, 10 units for perfomance testing to check the functionality of the analyzer’s heating unit and weighing system |
YCW512-AC-02 |
External calibration weight, 100 g ( E2 ) with DAkkS calibration certificate* |
YDP40 |
Standard laboratory printer |
YDP30 |
Premium GLP laboratory printer |
YCC03-D09 |
Adapter cable for connecting a YDP20-OCE printer |
YDP20-0CE |
Data printer |
YST01MA |
Forceps for samples |
YMD02B ( incl. short report ) |
Customer-specific service for individual method development at the Sartorius |
Specification |
|
Heating source |
AURI heater for fast and homogenious heating |
Application |
Standard and thermo-sensitive applications |
Num of measuring programs |
100 |
Weighing capacity |
200 g |
Line voltage |
115 - 230 V |
Width |
215 mm |
Readability |
1 mg, 0.01 % |
Depth |
400 mm |
Height |
210 mm |
Recommended moisture range |
1 – 99 % |
Data interface |
RS232C unidirectional |
Technical attribute |
|
Max. weighing capacity |
200 g |
Accuracy of the weighing system |
1 mg |
Weight ( approx.) |
6.2 kg |
Temp. range and settings |
40 °C – 200 °C, adjustable in 1-degree increments |
Built-in calibration weight |
No |
reproTEST |
Menu function to check the performance of the heating unit and the weighing system using a ReproEasy pad |
Heating mode |
Standard drying, gentle drying, MA35 mode |
Password protection |
Yes |
Operator guidance features |
Intuitive user-friendly interface ( touch screen ) and easy-to-understand menu prompt for user guidance |
Exchange of the heating unit by Plug&Dry® |
No |
Analysis mode |
Fully automatic, semiautomatic mg ( 1 mg – 50 mg | 5 sec. – 300 sec ), semiautomatic % ( 0.1 % – 5.0 % | 5 sec. – 300 sec ), timer settings ( 02 : 00 – 99.59 min ), manual |
Access to the sample chamber |
Removable hood with wide opening angle; SoftClose mechanism |
Number of program memories |
100 |
Display mode for results |
% moistrue, % dry weight, g moisture, g dry weight, ATRO ( ratio ) in % M / S |
In-use dust cover for keypad |
Yes |
Manual input of tare weights |
No |
Memory data storage |
Fully automatic storage of the last 999 results |
Data printer |
External ( optional ) |
Version compliant with FDA/ |
Yes |
ISO/GLP compliant print out |
GLP-compliant, inalterable standard or user-configurable printout | paper-saving mode for short record |