Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.
Evolution 260 Bio Spectrophotometer plus Tablet Control Module |
|
Full specifications |
|
Accuracy ( Photometric ) |
1 A : ±0.006 A |
2 A : ±0.010 A |
|
Measured at 440 nm using calibrated neutral density filters traceable to NIST |
|
Baseline Flatness |
±0.0010 A, 200-800 nm, 1.0 nm SBW, smoothing |
Beam Geometry |
Double-beam with Application Focused Beam Geometry |
Certifications/Compliance |
ISO 9001:2008 |
Data Interval |
10, 5, 2, 1.0, 0.5, 0.2, 0.1nm |
Description |
Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International |
Detector Type |
Dual Silicon Photodiodes |
Dimensions ( L x W x H ) |
62.2 x 48.6 x 27.9 cm |
Display |
Touchscreen LCD panel; 800 x 480; 17.8 cm ( 7 in. Diagonal ) |
Drift |
|
Electrical Requirements |
100-240 V 50-60 Hz selected automatically 150 W maximum |
Item Description |
Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International |
Keypad |
Sealed membrane |
Lamp |
Xenon Flash Lamp, 3-year warranty ( 7 years typical lifetime ) |
Noise |
0 A : |
1 A : |
|
2 A : |
|
260 nm, 1.0 nm SBW, RMS |
|
Operating System |
Microsoft Windows™ XP embedded |
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument |
|
Optical Design |
Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator |
Pharmacopoeia Compliance Testing |
( Guaranteed Performance Specifications ) |
Resolution ( toluene in Hexane ) : ≥1.8 A |
|
Photometric Accuracy ( 60 mg/L K2Cr2O7 ) : ±0.010 A |
|
Stray Light : ≤1 %T at 198 nm : KCI; ≤0.05 % AT at 220 nm : Nal, KI |
|
Wavelength Accuracy : ±0.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range |
|
Wavelength Repeatability : ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line |
|
Photometric Accuracy Instrument |
1 A : ±0.006 A |
2 A : ±0.010 A |
|
Measured at 440 nm using calibrated neutral density filters traceable to NIST |
|
Photometric Display |
-0.3 - 4.0 A |
Photometric Range |
>3.5 A |
Photometric Repeatability |
±0.0002 A |
Scan Ordinate Modes |
Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log ( 1/R ), log ( Abs ), Abs*Factor, Intensity |
Scan Speed |
|
Spectral Bandwidth |
Variable : 1.0 nm; 2.0 nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized |
Type |
Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International |
Wavelength Accuracy |
±0.5 nm ( 541.9, 546.1 nm mercury lines ) |
±0.8 nm ( full range 190-1100 nm ) |
|
Wavelength Range |
190 - 1,100 nm |
Wavelength Scan Speed |
|
Weight ( Metric ) |
14.4 kg |
Catalog Number |
912A0888 |
|
|
Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes power cords |
|
Full specifications |
|
Accuracy ( Photometric ) |
1 A : ±0.006 A |
2 A : ±0.010 A |
|
Measured at 440 nm using calibrated neutral density filters traceable to NIST |
|
Baseline Flatness |
±0.0010 A, 200-800 nm, 1.0 nm SBW, smoothing |
Beam Geometry |
Double-beam with Application Focused Beam Geometry |
Certifications/Compliance |
ISO 9001:2008 |
Data Interval |
10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm |
Description |
Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords |
Detector Type |
Dual Silicon Photodiodes |
Dimensions ( L x W x H ) |
62.2 x 48.6 x 27.9 cm ( 24 x 19 x 11 in ) |
Drift |
|
Electrical Requirements |
100-240 V 50-60 Hz selected automatically 150 W maximum |
Lamp |
Xenon Flash Lamp, 3-year warranty ( 7 years typical lifetime ) |
Noise |
0 A : |
1 A : |
|
2 A : |
|
260 nm, 1.0 nm SBW, RMS |
|
Operating System |
Microsoft Windows 7, Windows 8 |
Optical Design |
Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator |
Pharmacopoeia Compliance Testing |
( Guaranteed Performance Specifications ) |
Resolution ( toluene in Hexane ) : ≥1.8 A |
|
Photometric Accuracy ( 60 mg/L K2Cr2O7 ) : ±0.010 A |
|
Stray Light : ≤1 % AT at 198 nm: KCI; ≤0.05 % AT at 220 nm : Nal, KI |
|
Wavelength Accuracy : ±0.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range |
|
Wavelength Repeatability : ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line |
|
Photometric Accuracy Instrument |
1 A : ±0.006 A |
2 A : ±0.010 A |
|
Measured at 440 nm using calibrated neutral density filters traceable to NIST |
|
Photometric Display |
-0.3 - 4.0 A |
Photometric Range |
>3.5 A |
Photometric Repeatability |
±0.0002 A |
Scan Ordinate Modes |
Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log ( 1/R ), log ( Abs ), Abs*Factor, Intensity |
Scan Speed |
|
Spectral Bandwidth |
Variable : 1.0 nm; 2.0 nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized |
Type |
Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords |
Wavelength Accuracy |
±0.5 nm ( 541.9, 546.1 nm mercury lines ) |
±0.8 nm ( full range 190-1100 nm ) |
|
Wavelength Range |
190 to 1100 nm |
Wavelength Scan Speed |
|
Weight ( English ) |
32 lb |
Weight ( Metric ) |
14.4 kg |
Catalog Number |
840-211000 |