Gas Leak Checker Detector SP-220 Riken Keiki |
|||||
Specification for Type FUM & SC |
|||||
Model |
SP-220 TYPE FUM |
SP-220 TYPE SC |
|||
( Fumigation ) |
( Toxic, Combustible, CFC ) |
||||
Target gas |
Refer to the gas list |
||||
Detection principle |
Hot-wire semiconductor method |
||||
Sensor |
SH-8662 |
||||
Measuring range |
Depends on target gas |
||||
Alarm set point |
Depends on target gas |
||||
Accuracy |
Displays 0.1 ppm-bar when applied PH3 0.3 ppm. |
||||
Alarm pattern |
Gas alarm : Gas concentration reached or over the setting point. |
||||
Trouble alarm : Sensor connection / breaking, Low battery, Low flow Circuit error, Calibration error |
|||||
Alarm method |
Non-latching |
||||
Display of alarm |
Gas alarm : Flashing LED, Buzzer |
||||
|
Trouble alarm : Flashing LED, Buzzer, Display of error message |
||||
Alarm delay time |
0 sec. |
||||
Sampling method |
Sample draw |
||||
Response time |
10 sec.: Time to reach 0.1 ppm when applied PH3 0.3 ppm. |
||||
Output signal |
IrDA |
||||
Switch |
「AIR」「MODE」「POWER」 |
||||
Display device |
LCD |
||||
Display contents |
Gas name, Gas concentration,Time, Battery,Pilot indicator,Pump driving indicator |
||||
Power source |
2 AA dry cell batteries |
||||
Continuous operation |
More than 12 hrs. |
||||
Operating temp. & humidity |
-20~+55 °C ( -4 °F~+131 °F ), 0~95 % RH( Non-condensing C30 ) |
||||
Dimension & weight |
200 mm ( H ) x 43 mm ( D ) x 47 mm ( W ) ( Taper nozzle not included ), 215 g |
||||
Ingress proof |
IP 55 |
||||
Function |
Manual LCD backlight ( Automatically ON when alarming ), Peak value, Snap logging, Time, Cal alarm |
||||
Specification for Type M, L & ML |
|||||
Model |
SP-220 ( TYPE M ) |
SP-220 ( TYPE L ) |
SP-220 ( TYPE ML ) |
||
Detection principle |
Hot-wire semiconductor method |
||||
Target gas |
Town gas ( switchable to LPG ) |
LPG ( switchable to town gas ) |
Town-gas, LPG ( switching ) |
||
*2 gases are needed for calibration. |
|||||
Concentration display |
LCD level meter + Scale |
||||
Measuring range |
10~10000 ppm |
||||
Sampling method |
Sample draw |
||||
Alarm set point |
Default:30 ppm ( selectable from 10, 30,150, 500, 2000 ppm ) |
||||
Display |
Operating state disp., Flow check disp., Gas concentration disp., Alarm sound disp., Operation sound disp., Battery level icon, Level meter disp., Mode disp., Gas name and message disp. |
||||
Response time |
3 sec. |
||||
Gas alarm display |
Flashing LED, Buzzer |
||||
Gas alarm method |
Non-latching |
||||
Trouble alarm |
Sensor error, Low battery, Low flow, System error, Calibration error, Clock error, Pump error |
||||
Trouble alarm display |
Flashing LED, Buzzer, Trouble message |
||||
Trouble alarm method |
Latching |
||||
Power source |
2 AA dry cell batteries |
||||
Continuous operation |
Approx. 13 hrs. |
||||
Operating temp. |
-20~55 °C ( -4°F~131 °F C48 ) |
||||
Operating humidity |
0~95 % RH ( Non-condensing ) |
||||
Safety design |
Intrinsically safety ExiaIICT4 |
||||
Approvals |
Ex-proof : IECEx, ATEX / Other : CE marking |
||||
Ingress proof |
IP55 |
||||
Dimension |
200 ( H ) × 43 ( W ) × 39 ( D ) mm ( Taper nozzle not included ) |
||||
Weight |
215 g ( Dry cell batteries not included ) |