LB 126 Portable Dose & Doserate Monitor Berthold |
|
Features |
|
Compact and power-saving microprocessor electronics with charging circuit for 4 rechargeable batteries ( AA cells ) |
|
Measurement of the new quantities ambient dose and ambient dose rate equivalent H*( 10 ) |
|
Energy-compensated low dose counter tube LB 6006-H10 according to ICRU Report 39 |
|
Easy operation by means of 3 softkeys |
|
Signal and alarm indication |
|
Free selectable alarm thresholds for dose and dose rate |
|
Data storage for 1000 measurements |
|
RS232 and RS485 data interface for printout and communication; RS485 networking for up to 32 devices |
|
Detail |
|
The LB 126 is a portable Dose Rate Monitor which is used in the entire field of radiation protection. A sealed off proportional counter tube, approved in accordance with the new standard H*10, is used as detector. |
|
Three buttons suffice to navigate through the clearly arranged and userfriendly menu prompting. |
|
Up to 1000 measurements can be stored in the data memory and this data can be accessed and printed out via a RS232 and/or a RS485 interface. Serial data communication with the PC, i.e. reading and reset of the data memory, acquisition of the measurement values, reading the parameters and reset of the dose, takes place via F2C Protocol. |
|
Up to 32 devices can be linked via the integrated RS485 interface within a RS485 bus system. |
|
Digital electronics |
|
Microprocessor electronics with charging circuit for 4 rechargeable batteries ( AA cells ) |
|
Alternative operation with 4 batteries ( AA batteries ) |
|
32 kB Eeprom memory for parameters and 1000 measurement data |
|
Real time clock, battery-buffered |
|
Acoustics for single pulses and alarm |
|
Free selectable alarm thresholds for dose and dose rate |
|
RS232 and RS485 interface with adjustable baud rate |
|
Selectable Units |
µSv/h, µSv or mrem/h, mrem |
Operating temperature |
-10 to +40 °C |
Relative humidity |
30 % to 75 % |
External charging voltage |
+9 VDC, <0.6V |
Detector |
|
Energy-compensated proportional counter tube according ICRU Report 39; H*10 ( ambient dose equivalent ) |
|
Measuring Range |
50 nSv/h to 50 mSv/h |
Energy Range |
30 keV – 1.3 MeV |
Angle dependence |
± 45° |
Operation point |
1750 V |
Calibration factor |
0.214 µSv/h |
Intrinsic Background |
0.07 cps |
Dead time |
2.6 µs |
Digital electronics |
|
Lenght x diameter |
370 mm x 50 mm |
Weight |
950 g |
Display ranges |
|
Doserate |
0 to 50000 mSv/h |
Dose |
0 to 999 mSv |
Dose Integral time |
up to 99:59:59 ( hh:mm:ss ) |