Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.
Qrae 3 PGM-2500 RAEsystems Multi Gas Detector |
|
Specifications |
|
Size |
Diffusion : 5.5" H x 3.2" W x 1.5" W ( 140 x 82 x 42 mm ) |
Pumped : 5.7" H x 3.2" W x 1.7" D ( 145 x 82 x 42 mm ) |
|
Weight |
Diffusion : 12.9 oz ( 365 g with Li-ion battery and clip ) |
Pumped : 14.5 oz ( 410 g with Li-ion battery, clip, and external filter ) |
|
Sensors |
Up to four field-replaceable sensors: |
LEL : Catalytic bead for combustibles ( built-in Correction Factor library ) |
|
Oxygen : Liquid electrolyte O2 |
|
Toxic : electrochemical for H2S, CO, SO2, HCN |
|
Battery |
Rechargeable Li-ion Running time : 14 hours continuous non-wireless, diffusion |
11 hours continuous non- wireless, pumped |
|
10 hours continuous with wireless, diffusion |
|
8 hours continuous with wireless, pumped |
|
Note: All battery specifications at 68 °F ( 20 °C ); lower temperatures and alarm conditions will affect runtime. Display Graphic : Monochrome graphic display ( 128 x 80 ) |
|
Display size |
1.57" W x 1.06" H ( 40 x 27 mm ) with backlighting |
Automatic or on-demand screen rotation |
|
Keypad |
Two-button operation |
Direct Readout |
Real-time reading of gas concentrations |
Battery status |
|
Pump status ( if equipped with pump ) |
|
Wireless on/off and wireless reception quality |
|
STEL, TWA, peak, and minimum values |
|
Man Down and policy enforcement indicators |
|
Datalogging |
Multi-tone 95 dB buzzer ( at 11.8"/ 30 cm, typical ), vibration alarm, and flashing red LEDs and on-screen indication of alarm conditions |
Alarms: latching, non latching or manual override |
|
Additional diagnostic alarm and display message for low battery |
|
Pump stall alarm ( pumped version only ) |
|
Man Down Alarm with pre-alarm and real-time remote wireless notification |
|
Datalogging |
Continuous datalogging ( 3 months for 4 sensors at 1-minute intervals, 24/7 ) |
User-configurable datalogging intervals ( from 1 to 3,600 seconds ) |
|
Communication & Data Download |
Data download and instrument set-up and upgrades on PC via Travel Charger |
Wireless data and status transmission via built-in RF modem ( optional ) LOS > 650 ft ( 200 m )3 |
|
Wireless Network |
Mesh RAE Systems Dedicated Wireless Network |
Wireless Frequency |
ISM license-free bands, 868 MHz or 900 MHz |
Wireless Range ( Typical ) |
EchoView Host : |
ProRAE Guardian & RAEMesh Reader : LOS > 650 ft ( 200 m ) 3 |
|
ProRAE Guardian & RAELink3 Mesh : LOS > 30 ft ( 10 m ) 3 |
|
EM Immunity |
EMI and ESD test : 100 MHz to 1G Hz 30 V/m, no alarm |