Bante 904P Portable Conductivity/DO/C/°F Meter |
|
Model |
Bante 904P |
Conductivity |
|
Range |
0.01~20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm |
Accuracy |
±0.5 % F.S |
Resolutions |
0.01/0.1/1 |
Calibration Points |
1 to 5 points |
Calibration Solutions |
10 µS/cm, 84 µS/cm,1413 µS/cm,12.88 mS/cm,111.8 mS/cm |
Temperature Coefficient |
0.0~10.0 %/°C |
Compensation Modes |
Linear or Pure water |
Cell Constant |
K=0.1, 1, 10 or Custom |
Reference Temperature |
20 °C or 25 °C |
TDS |
|
Range |
0~10.00, 100.0, 1000 ppm, 10.00, 100 ppt ( Max. 200 ppt ) |
Accuracy |
±1 % F.S |
TDS Factor |
0.1~1.0 ( Default 0.5 ) |
Salinity |
|
Range |
0.00~80.00 ppt, 0.00~42.00 psu |
Accuracy |
±1 % F.S |
Measurement Modes |
Practical salinity ( psu ) or Natural seawater ( ppt ) |
Resistivity |
|
Range |
0.00~20.00 MΩ |
Accuracy |
±1 % F.S |
Resolution |
0.01/0.1/1 |
Dissolved Oxygen |
|
DO Range |
0.00~20.00 mg/L |
Accuracy |
±0.2 mg/L |
Resolution |
0.1/0.01 mg/L, selectable |
% Saturation Range |
0.0~200.0 % |
Accuracy |
±2.0 % |
Resolution |
0.1/1 % |
Calibration Points |
1 or 2 points |
Pressure Correction |
60.0~112.5 kPa, 450~850 mmHg |
Salinity Correction |
0~50 g/L |
Temperature |
|
Range |
0~105 °C, 32~221 °F |
Accuracy |
±0.5 °C |
Resolution |
0.1 °C |
Calibration Points |
1 point |
Temperature Units |
°C or °F |
General |
|
Temperature Compensation |
0~100 °C, 32~212 °F, Manual or Automatic |
Data Hold |
Manual or Automatic endpoint detection |
Stability Criteria |
Low or High |
Calibration Due Alarm |
1 to 31 days |
Power Off |
Manual or Automatic ( 10, 20, 30 minutes ) |
Reset Function |
Yes |
Memory |
Stores up to 500 data sets |
Output |
USB communication interface |
Connector |
6-pin mini plug |
Display |
LCD |
Power Requirements |
3 × 1.5 V "AA" batteries |
Battery Life |
Approximately 150 hours ( Turn off the backlit ) |
Dimensions |
170 ( L ) × 85 ( W ) × 30 ( H ) mm |
Weight |
300 g |
Order Code |
Accessories |
Bante904P-CN |
CON-1 conductivity electrode |
DO100 dissolved oxygen probe |
|
TP-10K temperature probe |
|
Conductivity standard solutions ( 84 µS/cm,1413 µS/cm,12.88 mS/cm ) |
|
DO electrolyte solution |
|
DO membrane cap |
|
AA batteries |
|
Carrying case |
|
Bante904P-UK |
K10 conductivity electrode ( Made in UK ) |
DO100 dissolved oxygen probe |
|
TP-10 K temperature probe |
|
Conductivity standard solutions ( 84 µS/cm,1413 µS/cm,12.88 mS/cm ) |
|
DO electrolyte solution |
|
DO membrane cap |
|
AA batteries |
|
Carrying case |