Dumatherm N Pro Protein Analysis Gerhardt |
|
Dumatherm N Duo Protein Analysis Gerhardt |
|
Specifications |
|
DUMATHERM® N Pro |
|
Sample size |
0,5 mg bis 1 g |
Sample capacity |
1 - 64 samples |
Analysis time |
3 - 5 min, depending on the sample type and sample size |
Recovery rate |
> 99,5 % |
Detection limits with Helium |
0,003 - 50 mg N absolut |
Detection limit with Argon |
0,1 - 50 mg N absolut |
Standard deviation |
< 0,5 % ( with standard sample preparation ) |
Operation |
Via PC* with DUMATHERM®-Manager |
Temp. range Combustion furnace |
400 - 1.100 °C |
Temp. range Reduction furnace |
400 - 1.100 °C |
Temp. range Desorption furnace |
50 - 350 °C |
Required gases and quality |
Helium ( alternatively argon ), grade 5.0 ( 99.999 % ) Oxygen, grade 5.0 ( 99.999 % ) Compressed air or nitrogen, grade 2.6 ( 99.6 %, oil- and water-free ) |
Gas installation |
Pressure regulators for high purity gas ; 1/4“ cylindric thread ( female ) |
Inlet pressure helium |
3 - 6 bar |
Inlet pressure oxygen |
3 - 6 bar |
Inlet pressure compr. air / nitrogen |
3 - 6 bar |
Ambient temp. |
15 °C < t < 35 °C |
Nominal voltage |
230 VAC |
Dimensions W x D x H |
870 x 710 x 860 mm ( closed ) 1108 x 710 x 1118 ( doors and protective hood opened ) |
Weight ca. |
85 kg |
Nominal wattage DUMATHERM® |
1380 W |
Nominal wattage autosampler |
90 W |
Current max. |
6:00 AM |
Wanted digital balance |
Optional, reading precision min. 0,1 mg |
Order Infomation |
|
14-0400 DT N Pro DUMATHERM® N. 64-place, complete with |
|
Autosampler for the automatic feeding of up to 64 samples* |
|
Starter Kit for 1.000 combustions |
|
Sample preparation tools |
|
DUMATHERM ® -Manager, control software* |
|
* Computer |
PC / Laptop and printer are not included in the shipment |
* Requirements for PC |
Windows 7®64 bit, 2 x USB-interface |
Specifications |
|
DUMATHERM® N Duo |
|
Sample size |
0,5 mg bis 1 g |
Sample capacity |
Max. 2 samples |
Analysis time |
3 - 5 min, depending on the sample type and sample size |
Recovery rate |
> 99,5 % |
Detection limits with Helium |
0,003 - 50 mg N absolut |
Detection limit with Argon |
0,1 - 50 mg N absolut |
Standard deviation |
< 0,5 % ( with standard sample preparation ) |
Operation |
Via PC* with DUMATHERM®-Manager |
Temp. range Combustion furnace |
400 - 1.100 °C |
Temp. range Reduction furnace |
400 - 1.100 °C |
Temp. range Desorption furnace |
50 - 350 °C |
Required gases and quality |
Helium ( alternative Argon ), quality grade 5.0 ( 99,999 % ) Oxygen, quality grade 5,0 ( 99.999 % ) Compressed air or nitrogen, quality grade 2.6 ( 99.6 %, oil- and water free ) |
Gas installation |
Pressure regulators for high purity gas ; 1/4“ cylindric thread ( female ) |
Inlet pressure helium |
3 - 6 bar |
Inlet pressure oxygen |
3 - 6 bar |
Inlet pressure compr. air / nitrogen |
3 - 6 bar |
Ambient temp. |
15 °C < t < 35 °C |
Nominal voltage |
230 VAC |
Dimensions W x D x H |
870 x 450 x 710 mm ( with autosampler ) |
Weight ca. |
65 kg |
Nominal wattage DUMATHERM® |
1380 W |
Current max. |
6:00 AM |
Wanted digital balance |
Optional, reading precision min. 0,1 mg |
Order Information |
|
14-0003 DT N DUO DUMATHERM® N Duo, 2-place, complete with : |
|
Autosampler for the manual feeding of max. 2 samples |
|
Starter Kit for 1.000 combustion |
|
Sample preparation tools |
|
DUMATHERM®-Manager, control software* |
|
* Computer |
PC / Laptop and printer are not included in the shipment |
* Requirements for PC |
Windows 7®64 bit, 2 x USB-interface |