PCA 3 Bacharach Combustion Gas Analyzers |
||
Measurements : |
||
O2 |
0 to 20.9 % |
|
CO ( low-range, H2-compensated ) |
0 to 4000 ppm |
|
CO ( high-range, optional ) |
4001 to 20,000 ppm |
|
NO ( optional ) |
0 to 3000 ppm |
|
NO2 ( optional ) |
0 to 500 ppm |
|
SO2 ( optional ) |
0 to 5000 ppm |
|
Stack temperature |
-4 to 2192 °F ( -20 to 1200 °C ) |
|
Primary/ambient air temp. |
-4 to 999 °F ( -20 to 537 °C ) |
|
Draft/differential pressure |
± 72 inH2O ( ± 179 mbar ) |
|
Display |
3.5 in. color LCD w/backlight |
|
Power |
4x AA batteries or optional wall adapter |
|
Run Time |
10 hours minimum ( alkaline batteries ) |
|
Size ( H x W x D ) |
9.0 x 3.0 x 2.5 in. (22.9 x 7.6 x 6.3 cm) |
|
Weight |
2.4 lb. ( 1.1 kg ) including batteries and probe |
|
Fuels [ 1 ] |
Natural gas, coal, oil 2/4/6, wood, kerosene, bagasse, propane, butane, LPG, digester gas, KOKS, LEG, biofuel, +2 optional custom fuels |
|
Operating Conditions |
Analyzer : 32 to 104 °F ( 0 to 40 °C ), 15 to 90 % RH ( non-condensing ), 1 ATM ± 10 % |
|
Probe tip [ 2 ] : 1000 °F ( 538 °C ) maximum, 10 inH2O ( 25 mbar ) maximum draft |
||
Warm-up Time |
60 seconds |
|
Memory |
1000 locations ( 500/ea for manually-saved and automatic/data-logged records ) |
|
Communications |
USB 2.0 ( mini-B ), IrDA |
|
Approvals |
CE mark, EN 50379-2 |
|
[ 1 ] Depending upon combustion equation setting ( North American or Siegert ) – see manual for details |
||
[ 2 ] For standard 12 in. probe, P/N 0024-3004 |
||
Order Information |
||
N. Amer. P/N |
Siegert ( Euro.) P/N |
Description |
0024-8440 |
0024-8460 |
PCA®3 225 with O2 and CO low-range |
0024-8441 |
0024-8461 |
PCA®3 235 with O2, CO low-range and NO |
0024-8442 |
0024-8462 |
PCA®3 245 with O2, CO low-range and CO high |
0024-8443 |
0024-8463 |
PCA®3 255 with O2, CO low-range and SO2 |
0024-8444 |
0024-8464 |
PCA®3 265 with O2, CO low-range, NO and NO2 |
0024-8445 |
0024-8465 |
PCA®3 275 with O2, CO low-range, NO and SO2 |
0024-8446 |
0024-8466 |
PCA®3 285 with O2, CO low-range, CO high-range and NO |
0024-8447 |
0024-8467 |
PCA®3 225 with O2, CO low-range and reporting kit |
0024-8448 |
0024-8468 |
PCA®3 235 with O2, CO low-range, NO and reporting kit |
0024-8449 |
0024-8469 |
PCA®3 245 with O2, CO low-range, CO high and reporting kit |
0024-8450 |
0024-8470 |
PCA®3 255 with O2, CO low-range, SO2 and reporting kit |
0024-8451 |
0024-8471 |
PCA®3 265 with O2, CO low-range, NO, NO2 and reporting kit |
0024-8452 |
0024-8472 |
PCA®3 275 with O2, CO low-range, NO, SO2 and reporting kit |
0024-8453 |
0024-8473 |
PCA®3 285 with O2, CO low-range, CO high-range, NO and reporting kit |
0024-8454 |
0024-8475 |
PCA®3 295 with O2, CO low-range, NO2 and SO2 ( 0024-8475 does not include carrying case ) |
0024-8455 |
0024-8476 |
PCA®3 295 with O2, CO low-range, NO2, SO2 and reporting kit |
All kits include ( unless otherwise noted ) : |
||
Probe with 12 in. sample tube ( approximately 6 ft. total length ), water trap, particulate filter and probe stop |
||
Spare filters ( qty. 3 ) |
||
Protective rubber boot |
||
4x AA batteries |
||
Fyrite® User Software |
||
USB cable |
||
User manual |
||
Hard carrying case |
||
Reporting kit adds : |
||
IrDA wireless printer |
||
4 additional AA batteries |