Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.
HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with optional GPS Hanna Instrument
Specifications |
|
pH Range |
0.00 to 14.00 pH |
pH Resolution |
0.01 pH |
pH Accuracy |
±0.02 pH |
pH Calibration |
( pH 4.01, 6.86, 7.01, 9.18, 10.01 |
mV Range |
±600.0 mV |
mV Resolution |
0.1 mV |
mV Accuracy |
±0.5 mV |
ORP Range |
±2000 mV |
ORP Resolution |
0.1 mV |
ORP Accuracy |
±1.0 mV |
ORP Calibration |
Automatic at one custom point ( relative mV ) |
EC Range |
0 to 200 mS/cm ( absolute EC up to 400 mS/cm ) |
EC Resolution |
Manual : 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm |
EC Accuracy |
±1 % of reading or ±1 µS/cm whichever is greater |
EC Calibration |
Automatic single point ( 84 µS/cm, 1413 µS/cm ) |
TDS Range |
0 to 400000 ppm ( mg/L ); ( the maximum value depends on the TDS factor ) |
TDS Resolution |
Manual : 1 ppm ( mg/L ); 0.001 ppt ( g/L ); 0.01 ppt ( g/L ); |
TDS Accuracy |
±1 % of reading or ±1 ppm ( mg/L ), whichever is greater |
TDS Calibration |
Based on conductivity or salinity calibration |
Resistivity Range |
0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Res Resolution |
Dependent on resistivity reading |
Res Calibration |
Based on conductivity calibration |
Salt Range |
0.00 to 70.00 PSU |
Salt Resolution |
0.01 PSU |
Salt Accuracy |
±2 % of reading or ±0.01 PSU whichever is greater |
Salt Calibration |
Based on conductivity calibration |
Seawater σ Range |
0.0 to 50.0 σt, σ₀, σ₁₅ |
Sea σ Resolution |
0.1 σt, σ₀, σ₁₅ |
Sea σ Accuracy |
±1 σt, σ₀, σ₁₅ |
Sea σ Calibration |
Based on conductivity or salinity calibration |
Ammonium-Nitrogen Range |
0.02 to 200.0 ppm Am ( as NH4 +-N ) |
Amm-Nitrogen Resolution |
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
Amm-Nitrogen Accuracy |
±5 % reading or 2 ppm |
Amm-Nitrogen Calibration |
1 or 2 point, 10 ppm and 100 ppm |
Chloride Range |
0.6 to 200.0 ppm Cl (as Cl- ) |
Chlo Resolution |
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
Chlo Accuracy |
±5 % of reading or 2 ppm |
Chlo Calibration |
1 or 2 point, 10 ppm and 100 ppm |
Nitrate-Nitrogen Range |
0.62 to 200.0 ppm Ni ( as NO3 - -N ) |
Nitrate-Nitrogen Resolution |
0.01 ppm to 1 ppm 0.1 ppm to 200 ppm |
Nitrate-Nitrogen Accuracy |
±5 % of reading or 2 ppm |
Nitrate-Nitrogen Calibration |
1 or 2 point, 10 ppm and 100 ppm |
Turbidity Range |
0.0 to 99.9 FNU; 100 to 1000 FNU |
Turb Resolution |
0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU |
Turb Accuracy |
±0.3 FNU or ±2 % of reading, whichever is greater |
Turb Calibration |
Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
DO Range |
0.0 to 500.0 %; 0.00 to 50.00 ppm ( mg/L ) |
DO Resolution |
0.1 %; 0.01 ppm ( mg/L ) |
DO Accuracy |
0.0 to 300.0 % |
DO Calibration |
Automatic one or two points at 0 and 100 % or one custom point |
Atmospheric Pressure Range |
450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; |
Atmos Pressure Resolution |
0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atmos Pressure Accuracy |
±3 mm Hg within ±15 °C from the temperature during calibration |
Atmos Pressure Calibration |
Automatic at one custom point |
Temp. Range |
-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
Temp. Resolution |
0.01 K, 0.01 °C, 0.01 °F |
Temp. Accuracy |
±0.15 °C; ±0.27 °F; ±0.15 K |
Temp. Calibration |
Automatic at one custom point |
Temp.Compensation |
Automatic from -5 to 55 °C ( 23 to 131 °F ) |
Logging Memory |
44,000 records ( continuous logging or log-on-demand of all parameters ) |
Logging Interval |
One second to three hours |
PC Connectivity |
USB ( with HI 929829 software ) |
Battery Type/Life |
1.2 V ( 4 ) NiMH, rechargeable batteries, size C type; up to 140 hours |
Waterproof Protection |
IP67 |
Environment |
0 to 50 °C ( 32 to 122 °F ); RH max 100 % |
Dimensions |
221 x 115 x 55 mm ( 8.7 x 4.5 x 2.2” ) |
Weight |
750 g ( 26.5 oz. ) |
GPS |
12 channel receiver 10 m ( 30 ft ) accuracy |