Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.
Spectrometer AT6102, AT6102A, AT6102B ATOMTEX |
|||
Specifications of spectrometers |
АТ6102 ( γ, n ) |
АТ6102А ( γ ) |
АТ6102В ( γ ) |
Gamma radiation detector |
Scintillator NaI ( Tl ), Ø40 x 40 mm; Geiger-Muller counter tube |
Scintillator NaI ( Tl ), Ø40 x 80 mm; Geiger-Muller counter tube |
|
Neutron radiation detector |
Two ³He proportional neutron counter |
– |
– |
Gamma radiation energy range |
20 keV...3 MeV |
||
Neutron radiation energy range |
0.025 eV...14 MeV |
– |
– |
Radionuclide identification |
Medical, Industrial and Natural ( Library of identified radionuclides can be modified ) |
||
Typical resolution at 662 keV ( 137Cs ) |
7.5 % |
8 % |
|
Maximum input statistical load |
≥1.5·105 s-1 |
||
Detection time of 137Cs source with 50 kBq activity at 20 cm distance |
≤2 s |
||
Detection time of 252Сf source with 0.9 probability and neutron yield 1.8·104 neutron/s at 20 cm distance |
≤5 s |
– |
– |
Measurement range of gamma radiation ambient dose equivalent rate |
0.01...300 µSv/h [NaI(Tl)] 10 µSv/h...100 mSv/h [G-M] |
0.01...150 µSv/h [NaI(Tl)] 10 µSv/h...100 mSv/h [G-M] |
|
Limit of dose rate measurement intrinsic relative error |
±20 % |
||
Sensitivity to gamma radiation |
|||
241Am |
6600 cps/µSv·h-1 |
11600 cps/µSv·h-1 |
|
137Сs |
850 cps/µSv·h-1 |
1700 cps/µSv·h-1 |
|
60Сo |
430 cps/µSv·h-1 |
840 cps/µSv·h-1 |
|
Response time for dose rate change from |
|||
Energy dependence relative to 662 keV |
±20 % [ NaI ( Tl )] ( in 50 keV...3 MeV energy range ) |
||
±25 % [ G-M ] ( in 60 keV...3 MeV energy range ) |
|||
Sensitivity to direct neutron radiation |
|||
Pu-Be |
0.28 impulse·cm2/neutron |
– |
– |
252Сf |
0.5 impulse·cm2/neutron |
||
Number of ADC channels |
1024 |
||
Operation mode setup time |
≤1 min |
||
Continuous run time |
≥18 h |
≥25 h |
|
With external smart probes connected |
≥15 h |
≥17 h |
|
Burn-up life |
≥100 Sv |
||
Protection class |
IР65 |
||
Working temp. range |
-20 °C...+50 °C |
||
Relative air humidity |
≤95 % ( with air temperature ≤35 °C without condensation ) |
||
Connection to PC |
USB, Bluetooth |
||
Overall dimensions, Weight |
230 х 115 х 212 mm |
230 х 115 х 177 mm |
230 х 115 х 177 mm |
Spectrometers meet Safety standard requirements : IEC 61010-1:2001, EMC |
|||
Spectrometers have the pattern approval certificates of Republic of Belarus, Russian Federation, Kazakhstan. |
|||
Specifications |
|||
of external detection units |
BDPA-01 (α) |
BDPB-01 (β) |
BDKN-03 (n) |
Detector |
ZnS(Ag) scintillator, Ø60 mm |
Scintillation plastic, Ø60 mm |
³He counter in polyethylene moderator |
Measurement range |
0.5 ... 1·105 part.·min-1·cm-2 |
3 ... 5·105 part.·min-1·cm-2 |
0.1 µSv/h ... 10 mSv/h |
( Flux density ) |
( Flux density ) |
( Dose rate ) |
|
Energy range |
4 ... 7 MeV |
155 keV ... 3.5 MeV |
0.025 eV...14 MeV |
Sensitivity |
0.15 cps/( part.·min-1·cm-2) |
0.3 cps/( part.·min-1·cm-2 ) ( 90Sr+90Y ) |
0.355 cps/µSv·h-1 |
Limit of intrinsic relative measurement error |
±20 % |
||
Protection class |
IР54 |
||
Overall dimensions, Weight |
Ø87 x 205 mm, 0.55 kg |
Ø87 x 205 mm 0.65 kg |