Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.
Low Temp. Incubator Forced Convection Lab Companion |
|||||
Specifications |
|||||
Model |
IL3-15 |
IL3-25 |
|||
Chamber volume ( L/cu ft ) |
150/5.32 |
242/8.5 |
|||
Refrigerator ( Hp ) |
1/6 HBP |
1/6 HBP |
|||
Temp. |
Range ( ℃/℉ ) |
0 to 80/+32 to 176 |
|||
1) Fluctuation at 37 ℃ ( ±℃/ ℉ ) |
0.1/0.18 |
||||
1) Variation at 37 ℃ ( ±℃/℉ ) |
0.8/1.44 |
1.0/0.18 |
|||
Dimension ( W × D × H ) |
Interior ( mm/inch ) |
600 × 500 × 500 / 24 × 20 × 20 |
500 × 520 × 930 / 20 × 20.5 × 36.6 |
||
Exterior ( mm/inch ) |
720×760×1070/28.9×29.9×42.1 |
620×770×1680/24.4×30.3×66.1 |
|||
No.of wire shelf ( standard/max ) |
2/11 |
3/25 |
|||
Net weight ( Kg/lbs ) |
100/220 |
135/297 |
|||
Electrical requirements ( 230V ) |
60 Hz, 4.5 A |
50Hz, 4.5A |
60Hz, 6.4A |
50Hz, 6.4A |
|
Cat. No. |
AAH220422K |
AAH220412K |
AAH220522K |
AAH220512K |
|
Electrical requirements (120V) |
60 Hz, 8.3 A |
60 Hz, 10.6 A |
|||
Cat. No. |
AAH220462U |
AAH220562U |
|||
Performance |
|||||
Temperature range from 0 °C to 60 °C. |
|||||
- Silent cooling system reduces water evaporation within the chamber. |
|||||
Microprocessor PID control. |
|||||
Three point temperature calibration / Automatic tuning. |
|||||
Forced air convection using an optimal cross flow fan for chamber temperature uniformity. |
|||||
Convenience |
|||||
Large chamber volume : maximum 242 L. |
|||||
Bright VFD display ( 0.1 ℃ resolution ) |
|||||
Dual wait on/off timer modes. ( 1 min. to 99 hr. 59 min.) with heating level indication and quick adjustable dial knob. |
|||||
Dual wait on/off timer modes. ( 1 min. to 99 hr. 59 min.) |
|||||
Convenient preset function for 3 most commonly used temperature settings. |
|||||
Built-in electrical outlet with a safety cover inside the chamber. |
|||||
Convenient sample monitoring without affecting chamber temperature via the inner tempered-glass door. |
|||||
Rounded inner chamber corners for easy cleaning and optimal airflow. |
|||||
Quick-release front grill for easy cleaning of the condenser. |
|||||
Built-in RS-232 port and USB port for external control and data collection. |
|||||
Safety |
|||||
Automatic run after power interruption. |
|||||
Over-current protection. |
|||||
Triple independent temperature monitor system. |
|||||
- Temperature deviation alarm ( High/Low ) |
|||||
- Electronic temperature limiter ( High/Low ) |
|||||
- Mechanical over-temperature limiter ( High ) |
|||||
Keypad lock function prevents accidental changes during operation. |
|||||
Audible and visible open door alarms. |