Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.
Incubator General IB-05G, IB 15G, IB 25G Lab Companion |
||||
Specifications |
||||
Model |
IB-05G |
IB-15G |
IB-25G |
|
Chamber volume ( L/cu ft ) |
60 / 2.1 |
102 / 3.6 |
151 / 5.3 |
|
Temp. |
Range ( ℃/℉ ) |
Amb. +5 to 70 / Amb. +9 to 158 |
||
Fluctuation 1) at 37 ℃ ( ±℃/℉ ) |
0.1 / 0.18 |
0.1 / 0.18 |
0.2 / 0.36 |
|
Variation 1) at 37 ℃ ( ±℃/℉ ) |
0.6 / 1.08 |
0.2 / 0.36 |
0.6 / 1.08 |
|
Dimension ( W × D × H ) |
Interior ( mm/inch ) |
400 × 360 × 420 |
480 × 410 × 520 |
610 × 460 × 540 |
15.7 × 14.2 × 16.5 |
18.9 × 16.1 × 20.5 |
24 × 18 × 21.3 |
||
Exterior ( mm/inch ) |
595 × 555 × 745 |
675 × 605 × 855 |
805 × 655 × 885 |
|
23 × 22 × 29 |
27 × 24 × 34 |
32 × 26 × 35 |
||
No. of wire shelf ( standard/max ) |
2 / 7 |
2 / 11 |
2 / 11 |
|
Net weight ( Kg/lbs ) |
45 / 99 |
55 / 121 |
62 / 136 |
|
Electrical requirements ( 230V,50/60 Hz ) |
1.3A |
2.2A |
3.1A |
|
Cat. No. |
AAH21162K |
AAH21172K |
AAH21182K |
|
Electrical requirements ( 120V,50/60 Hz ) |
2.8A |
4.6A |
6.4A |
|
Cat. No. |
AAH21166U |
AAH21176U |
AAH21186U |
|
1 ) Technical data according to DIN 12880. |
||||
Performance |
||||
Temperature range from ambient +5 °C to 70 °C. |
||||
Microprocessor PID control / Temperature calibration / Automatic tuning. |
||||
Vibration-free design ideal for yeast cultivation. |
||||
- Air-jacked natural convection is beneficial for Uniform temperature distribution and minimal sample contamination caused by external air intrusion. |
||||
Durable incoloy heating element with radiator fans for efficient heat dissipation. |
||||
Convenience |
||||
Intuitive control panel with bright LED display. ( 0.1 ℃ resolution ) |
||||
Dual wait on/off timer modes. ( 1 min. to 99 hr. 59 min.) |
||||
Convenient preset function for 3 most commonly used temperature settings. |
||||
Convenient sample monitoring without affecting chamber temperature via the inner tempered-glass door. |
||||
Corrosion-resistant stainless steel interior with rounded corners for easy cleaning and optimal airflow. |
||||
Fully insulated dual-wall door with magnetic rubber gasket. |
||||
Built-in cable port to use other instruments inside the chamber. ( diameter: 38 mm, provided silicon or rubber cap ) |
||||
RS-232 interface for external control and data collection. |
||||
Stackable up to 2 units using the optional stacking kit. ( optional ) |
||||
Safety |
||||
Automatic run after power interruption. |
||||
Keypad lock function prevents accidental changes during operation. |
||||
Over-temperature and over-current protection. |
||||
Audible and visible open door alarms. |