Vapodest 20S & 30S Programmable Distillation Systems Gerhardt |
||
Technical Data |
||
Model |
Vap 20S |
Vap 30S |
Cooling water consumption per min |
5 l |
5 l |
Distillation time / sample |
2-4 min. |
2-4 min. |
Recovery rate % |
> 99,5 |
> 99,5 |
Reproducibility % |
+/- 1 |
+/- 1 |
Detection limit N |
0,1 mg |
0,1 mg |
Nominal voltage |
230 V AC¹⁾ |
230 V AC¹⁾ |
Frequency |
50-60 Hz |
50 Hz |
Nominal wattage |
1600 W |
1600 W |
Weight |
25 kg |
27 kg |
Dimensions ( W x d x H ) |
440 x 340 x 690 mm |
440 x 340 x 690 mm |
Order No. |
12-0020 |
12-0025 |
Versatile applications |
VAPODEST watersteam - rapid distillation systems are used worldwide e.g. for the determination of nitrate, nitrite, ammonium, Kjeldahl-digestion solutions, volatile acids, sulphur dioxide, ethanol, formaldehyde, phenols as well as other compounds. The fields of application can be found in various matrices, e.g. in: |
Food |
Feed |
Luxury food ( beer, vine, liqueur, spirits ) |
Cosmetics |
Detergents |
Environmental samples ( plants, water, soils, sewage sludge ) |
Rotten material from biogas plants e.t.c. |
Protein determination in : |
Grain and grain products e.g. aoa C 979.09, 920.87 |
Eggs and egg products e.g. § 64,05.00,15 |
Milk and milk products, e.g. § 64,01.00,10 |
Meat and meat products, e.g. aoa C 928.08 |
Raw material for breweries, e.g. aoa C 920.53,950.09 |
Tobacco |
Animal feed e.g. aoa C 990.03 |
Starch |
Malt, wort, beer |
And many more |
Nitrogen determination in : |
Soil ( fertilizers ) e.g. aoa C or Din 19684 part 4 or aoa C 973.48 |
Water e.g. DeV, H11, H28 |
Substrates |
Cellulose |
Pulp |
Paper |
Petroleum |
Steel |
Coal |
And many more. |
Water steam distillation |
Phenol |
Alcohol |
Total cyanide |
Determination of ammonium |
Preservatives |
Sulphur dioxide |
Volatile nitrogenous base preservatives |
Natural rubber |
And many more |
VAPODEST 20S |
VAPODEST model for low sample throughput with simple program procedure : |
Automatic NaOH addition, Steam power variable from 40 - 100 %.The 5 x 7 segment LED shows the individual program steps and can display as well up to 9 different error messages. |
VAPODEST 30S |
The intermediate model is specifically set up with all the following parameters for Kjeldahl distillations, namely : |
Automatic addition of NaOH, H2O as well as removal of the sample residues, variable steam power from 40 - 100 %. The 5 x 7 segment LED shows the program steps and can display up to 9 different error messages. |