RAE QRAE II PGM-2400 Confined Space Multi Gas Monitor |
|
Specifications |
|
Size |
Diffusion : 5" L x 2.8" W x 1.5" H ( 12.5 x 7.2 x 3.8 cm ) |
Pump : 5" L x 2.8" W x 2" H ( 12.5 x 7.2 x 5.0 cm ) |
|
Weight |
Diffusion : 9 oz ( 250 g ) |
Pump : 12 oz ( 350 g ) |
|
Sensors |
• Catalytic bead for combustibles |
• Oxygen : SPE O2™ ( non-consumable Solid Polymer Electrolyte technology ) |
|
• Toxic : electrochemical for H2S or CO |
|
Battery |
Interchangeable Lithium-ion or alkaline battery packs |
Operating Period |
Diffusion : Up to 14 hours continuous operation with Lithium-ion battery, up to 10 hours with alkaline battery ( typical, without alarm ) |
Pump : Up to 10 hours with Lithium-ion battery, up to 8 hours with alkaline battery |
|
Display Graphic |
4 lines, with LED automatic back light in dim light or alarm condition |
Keypad |
Two-button operation |
Direct Readout |
• Instant reading from up to four sensors |
• Oxygen as percentage by volume |
|
• Combustible gas as percentage of lower explosive limit ( LEL ), scalable using correction factors |
|
• Toxic gases in parts per million |
|
• High and low values for all gases |
|
• Battery and shutdown voltage |
|
• Date, time, elapsed time, temperature |
|
Alarms |
• 95 dB buzzer ( at 30 cm, typical ), vibration alarm, and flashing red LED |
• High : 3 beeps, vibration and flashes per second |
|
• Low : 2 beeps, vibration and flashes per second |
|
• STEL and TWA : 1 beep, vibration and flash per second |
|
• Alarms : latching with manual override or automatic reset |
|
• Additional diagnostic alarm and display message for low battery |
|
• Pump stall alarm ( QRAE II Pump only ) |
|
EMI/RFI |
Highly resistant to EMI/RFI. Compliant with EMC directive |
2004/108/EC additional +60 volts/meter |
|
IP Rating |
IP-65 |
Datalogging |
Standard 12 days at one-minute intervals |
Calibration |
Two-point calibration for zero and span ( manual, or automatic with the AutoRAE Lite ) |
Sampling Pump |
Optional, internal pump 300 cc/min |
Hazardous Area Approval |
• US and Canada : R US C CI, D1, Groups A, B, C, D, T4 |
• Europe : ATEX II 2G Eex iad IIcT4 |
|
• IECEX : Ex ia dIICT4 |
|
Temperature |
-4 ° to 113 °F ( -20 ° to 50 °C ) for T4 temperature code |
Humidity |
0 % to 95 % RH ( non-condensing ) |
Attachments |
Stainless-steel alligator clip |